Digital Multimeter: 16
 |
• Accurate temperature measurement from -40 to 750°F (-40 to 400°F)
• Capacitance up to 10,000 micofarads
• Min/Max record with relative time clock
• Diode Test
• Vcheck
• Temperature
• Sleep Mode
• Fast continuity beeper
• 4000 County digital display |
| TSI # / Part # |
Description |
| FLUKE-116 |
Digital Multimeter: 16 |
| |
Digital Thermometer,
Dual Input: 52-2
 |
• Laboratory accuracy; ±[0.05% + 0.3°C]
• Large backlit display
• Min/Max/Average recording
• Electronic offset function maximizes overall accuracy
• Measures temperature in °C, °F or Kelvin (K)
• Drop protected to 1 meter
• User-friendly front panel that’s easy to use
• Sleep mode
|
| TSI # / Part # |
Description |
| FLUKE-52-2 |
Digital Thermometer, Dual Input: 52-2 |
| |
Clamp Meter: 333
 |
• Auto shut-off
• Small body and jaws fit perfectly in your hand, as well as, tight places
• Large backlit display
• Inrush current function
• Improved low current measurement accuracy
• Handy display hold keeps measurements on the display
•Meter controls are positioned so current measurements can be done with one hand
|
| TSI # / Part # |
Description |
| FLUKE333 |
Clamp Meter |
| |
Fluke HVAC Combo
Kit: 16/322
 |
Combo Kit Includes:
• Fluke 16 Multimeter with Temperature
• Fluke 322 Compact Clamp Meter
• Fluke TL75 Hand Point Test Lead Set
• Fluke 80BK Integrated Temperature Probe
• Fluke C800 Durable Carrying Case
|
| TSI # / Part # |
Description |
| FLUKE-16/322 |
Fluke HVAC Combo Kit |
| |
|
Test Leads
TL75 Hard Point™
Test Lead Set
 |
• One pair (red, black) of comfort grip probes
• 48 inches (1.22 meter) PVC insulated test leads w/ right-angle shrouded banana plugs
• Recommended for general purpose measurements
• CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed
• One year warranty
|
| TSI # / Part # |
Description |
| #TL75 |
Test Leads |
| |
VoltAlert™ Voltage
Detector
 |
The pocket-sized voltage detector
The next generation VoltAlert™ AC non-contact voltage testers from Fluke are easy to
use — just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows
red and the unit beeps, you know there’s voltage present. |
| TSI # / Part # |
Description |
| FLUKE-1AC-A1 |
ACV Detector 90-1000V, Flat Tip |
| FLUKE-1LAC-A |
Low Voltage Detector 20-90VAC, Round Tip |
| |
Contact Probes
|
• Inexpensive and offers good accuracy along with fast response
• Compatible with K -type thermometers
• Measurements Range: -40 to 260°C (-40 to 500°F)
|
80PK-1 Bead Probes
 |
TSI # / Part # |
Description |
| 80PK-1 |
80PK-1 Bead Probes |
80PK-8 Pipe Clamp
Temp. Probe
 |
• Designed for pipe sur faces from 6.4 mm (1/4”) diameter to 34.9 (1-3/8”) mm diameter
• Spring action jaw will not loosen over time, ensuring repeatable measurements
• Robust design for extended service life
• Measurement range: -29°C to 149°C (-20°F to 300°F)
• Repeatability: 0.56°C (1°F) |
| 80PK-8 |
80PK-8 Pipe Clamp Temp. Probe |
Thermocouple
Adapter |
• Adapts Type-K thermocouple mini-connector to dual shrouded banana plug inputs
• Measurement range and accuracy: probe dependent
• Suitable for low voltage applications(below 30 V AC, 60 V DC)
• One year warranty |
 |
80AK-A |
Thermocouple Adapter |
| |
|
Gas Pressure
Manometer:
Model 1213 |
Provide visual indication of pressure with the Series 1213 Gas Pressure Manometer.
Designed for use with natural gas, the manometer can also be used to monitor any
compatible gases up to 15” of water column. Tap water is used as the sensing media
and a magnetic clip provides temporary or permanent mounting. Economically priced
and made of durable plastic for years of trouble-free service. Includes three feet of vinyl
tubing and 1/8” nylon male NPT to barb fitting. |
| |
1213-15 |
Gas Pressure Manometer |
| |
| Magnehelic Gages |
Select the Dwyer Magnehelic gage for high accuracy--guaranteed within 2% of full
scale--and for the wide choice of 81 models available to suit your needs precisely.
Using Dwyer's simple, frictionless Magnehelic movement, it quickly indicates low air or
non-corrosive gas pressures—either positive, negative (vacuum) or differential. The
design resists shock, vibration and over-pressures. No manometer fluid to evaporate,
freeze or cause toxic or leveling problems. It's inexpensive, too. |
 |
S2002 |
Range to inches of water: 0 to 2.0; Minor Div: 0.05 |
| S2005 |
Range of inches of water: 0 to 3.0; Minor Div: 0.1 |
| |
| Gage Tubing |
Part # |
Description |
 |
A-201 |
3/16 ID, 1/4 OD x 9' Tubing |
| |
Static Pressure
Sensor |
Part # |
Description |
 |
A-308 |
Fitting for 3/16" and 1/8" ID Tubing |
| |
| Air Filter Kit |
Air Filter Kit - Adapts any standard Magnehelic® for use as an air filter gage. Includes
aluminum surface mounting bracket with screws, (2) 5 ft. (1.5m) lengths of 1/4"
aluminum tubing, (2) static pressure tips & (2) molded plastic vent valves. |
| |
Part # |
Description |
| A-605 |
Dwyer Air Filter Kit |
| |
|
| |
D-Tek™: Refrigerant
Leak Detector
 |
Features at a Glance:
• 0.10 oz. (3 gm)/year sensitivity
• Equally sensitive to all refrigerants, including R-22, R134a, R-404a, R-410a, R-507 (AZ-50) and all CFCs, HCFCs and HFCs
• 800-hour infrared cell life for low cost of ownership
• Infrared cell does not weaken over time, so response
• Remains consistent and accurate
• Infrared cell cannot be overloaded or "poisoned" by exposure to large amounts of refrigerant
• Selective to refrigerants only; will not react to smoke, humidity, airflow or temperature changes
• High-efficiency air sampling pump provides quick response & quick clearing ("zeroing")
• On-board diagnostics indicate charging status & warn of low battery / infrared cell failure
• NiMH power stick is environmentally friendly, won't corrode, & provides greater charging capacity
• Includes hard plastic case, NiMH power stick, 2V & 120V adapter/recharger, tip filters & infrared cell |
| Part # |
Description |
| 712-202-G1 |
Refrigerant Leak Detector |
| |
Tek-Mate®: Portable
Leak Detector
 |
If you're looking for a moderately priced, hand-held leak detector with proven D-TEK
heated diode sensor technology-- TEK-Mate is the tool for you. Equal sensitivity to
CFCs, HCFCs, and HFCs eliminates resetting or switching for different refrigerants.
Automatically compensates for changing background contamination. And it's reliable,
even under damp conditions. TEK-Mate uses a variable intensity audible alarm and a
single flashing LED to help pinpoint leaks. It's dependable for long-lasting performance
on two D-size batteries. |
| Part # |
Description |
| 705-202-G1 |
TEK-Mate Portable Leak Detector |
| |
Wey-TEK™: Refrigerant
Charging Scale
 |
The Wey-TEK Refrigerant Charging Scale continues to set new standards in
affordability and accuracy for refrigerant scales, enabling you to easily weigh and
charge from the same large platform. Now it offers even more value, with a higher
weight capacity-220 lbs., twice that of many other scales at a competitive price.
Wey-TEK is very easy to use. I ts high-accuracy load cell gives the cor rect reading
every time (no matter where the cylinder is on the weighing platform), and you can read
its large LCD display at a distance, even in direct sunlight. |
| Part # |
Description |
| 713-202-G1 |
Wey-TEK Refrigerant Charging Scale |
| |
GAS-Mate™:
Combustible Gas
Leak Detector
 |
Features:
• Sensitive to 5 ppm methane (twice as sensitive as nearest competitor)
• Also detects natural gas, propane, butane, cyclopentane, ethane, ethanol, isobutene,
and ammonia
• Variable audio alarm and flashing LED indicates leak strength
• Auto zeroing for ignoring background gas levels in leak test area
• Small sensor and probe tip permit leak checking in tighter places
• Runs continuously for 60 hours on two alkaline “D” cells |
| Part # |
Description |
| 706-600-G1 |
GAS-Mate Comb, Gas Leak Detector |
| |
|
| |
G5 Twin Recovery Unit
 |
The G5 Twin was designed from the ground up to provide the best recovery speeds in
all conditions with the smallest size por table unit-all at a price that will make you smile.
The G5 Twin starts with an extra heavy-duty crankcase for driving twin pistons. These
twin cylinders allow for greater throughput for both liquid and vapor phase.
Just take a look a t these performance comparisons. Across the board, the G5 Twin is
up to 188% faster in all conditions. |
| Part # |
Description |
| G5 TWIN RECOVERY |
G5 Twin Recovery Unit |
MF3613 |
Filter Screen for the G5 Twin |
| |
SPECTROLINE LEAK DETECTION
|
| |
Glo-Stick Capsules :
For small to medium
size systems
|
Features:
• Easy to use- Prefilled, disposable capsules allow dye to be injected into pressurized
systems using refrigerant.
• Clean and precise- The entire contents is washed into the system
• Choice of sizes: Available in 4 sizes/concentrations to match capacity of system.
• Safe- Will withstand pressure of more than 1000 psi |
For Mineral Oil
Lubricant Systems
 |
Part # |
Description |
| SPE-GS-101CS |
Up to 2.9 pounds of refrigerant or up to 15 fluid ounces of lubricant |
| SPE-GS-1CS |
Up to 4.9 pounds of refrigerant or up to 1.6 quarts of lubricant |
| SPE-GS-2CS |
5 to 9.9 pounds of refrigerant or 1.7 quarts of lubricant |
| SPE-GS-3CS |
10 to 25 pounds of refrigerant or 3.3 quarts to 2 gallons of lubricant |
For Polyol Ester
Lubricant Systems |
Part # |
Description |
| |
SPE-GS-1/ECS |
Up to 4.9 pounds of refrigerant or up to 1.6 quarts of lubricant |
| SPE-GS-2/ECS |
5 to 9.9 pounds of refrigerant or 1.7 quarts of lubricant |
| SPE-GS-3/ECS |
10 to 25 pounds of refrigerant or 3.3 quarts to 2 gallons of lubricant |
| SPE-GS-70/E |
Starter Assortment Pack, Contains One GS-101/E, Two GS-1/E,
Two GS-2/E, and One GS-3/E |
| Glo-Stick Accessories |
Part # |
Description |
| |
SPE-BV-50 |
Bleed Valve for all GLO-STICK capsules except GS-101, PAG |
| |
EZ-Ject Multi-Dose Dye
Injection System
 |
Contains:
• EZ-50, EZ-Ject dye injector assembly
• EZ-25, 18” hose assembly complete with check valve and 1/4” flare low-loss fitting
• EZ-4 (2) EZ-Ject mineral oil dye cartridges
• 119690 purge fitting
• Service labels |
| Part # |
Description |
| SPE-EZ-100 |
EZ-100 Dye Injection Kit |
| |
Spectronics: Optimax
1000 Rechargeable UV
Flashlight
 |
Features:
• Ideal for medium to large systems
• 10 brighter than regular LED lights
• Over 6 hours of operation between charges
• Power comparable to super -high intensity 100 W lamps
• Inspection range of up to 20 feet (6.1m)
• Powered by rechargeable NiMH battery included
• UVS-40 fluorescence-enhancing glasses |
| Part # |
Description |
| SPE-OPX-1000 |
Rechargeable UV Leak Detection Flashlight |
| |
Spectronics: Optimax
500CS Mini Mag
 |
Features:
• 100,000 hour LED bulb
• Over 4 hours of peak performance
• Choice of continuous or momentary
• Illumination
• Powered by 3 “AA” batteries (included)
|
| Part # |
Description |
| SPE-OPX-500CS |
Optimax Jr. Mini Flashlight |
| |
Spectronics: UV
Goggles |
Fluorescence-enhancing glasses |
 |
Part # |
Description |
| SPE-UVS-40 |
UV Goggles |
| |
|
| |
| Deep Vacuum Pumps |
• 1/2 HP, capacitor start, thermal overload protected motor
• Break-resistant s teel handle w/ cushioned cool-grip
• All brass fittings
• All metal construction
• Housing protected drain valve
• Finned aluminum housings for lower operating temperature
• 2 stage, direct drive
• check valve prevents oil backflow during power failure
• Low profile rocker switch
• 25 micron field tested (thermister gauge reading)
• Completely field repairable
|
 |
Part # |
Description |
| DV85N |
3CFM, 1/4" x 3/8" intake ports, male flare, 27oz oil capacity |
| DV142N |
5CFM, 3/8" x 1/4" x 3/8" intake ports, male flare, 23oz oil capacity |
| DV-200N |
7CFM, 3/8" x 1/4" x 3/8" intake ports, male flare, 23oz oil capacity |
| |
| Digital Vacuum Gauge |
JB’s Digital Vacuum Gauge reads vacuum in 7 international units. Microns. PSIA, InHg,
mBars, Pascals, Torr, and mTorr. The DV-22N has a micron range of 20 to 9,000
microns. It is a good idea to attach the micron gauge to the vacuum pump before
evacuation to make sure the pump pulls down to at least 50 microns . If it doesn’t your
pump is contaminated and the oil should be changed. A compound gauge only indicates
that a vacuum is being produced, but doesn’t not tell you if moisture or acids are still in
the system. The DV-22N, however, is the only tool to accurately read the low pressure
produced when evacuation/dehydration is complete. |
 |
Part # |
Description |
| DV-24 |
DV-22N Digital Vacuum Gauge w/Carrying Case |
| |
Superheat, Pressure &
Temperature Gauge |
Instant readings at the touch of a button. Gauges feature built-in R-22 table or use plug-
in refrigerant pressure- temperature memory key. Gauges are pulsation-proof and
accurate at any elevation from sea levels to 16,000 feet without any adjustment. |
 |
Part # |
Description |
| SH-35N |
SH-35 Superheat Gauge w/Case |
| |
1/4" Standard Manifold
 |
• Surge dampened gauges. Reduced pointer movement
• "Knuckle Clearance" angled bar
• Pull-out proof hanging hook
• Color-coded refrigerant dials
• Hose holder mounts to front or back of bar
• Color-coded durable nylon handwheels |
| Part # |
Description |
| M2-8 |
1/4" Standard Manifold (no hose set) |
| |
Manifold Gauges: R-12,
R-22 and R-502 Gauges |
• Compound Gauges:
• 30" vacuum to 120 psi, retard to 350 psi
• Pressure Gauges:
• 0 to 500 psi
|
 |
Part # |
Description |
| M2-250 |
Blue-Compound Gauge, Plastic Case |
| M2-500 |
Red-Pressure Gauge, Plastic Case |
| |
Manifold Gauges:
R-410a Gauges |
• Low side 30" vacuum to 250 psi, retard to 500 psi
• High side 0-800 psi
|
 |
Part # |
Description |
| M2-410 |
Compound Gauge - 1/8 MPT Conn. |
| M2-415 |
Pressure Gauge - 1/8 MPT Conn. |
| |
Manifold / Gauge
Replacement Parts |
Part # |
Description |
| |
MR-505 |
Piston w/Seat & O-Rings |
| MR-517 |
Replacement Plastic Lens |
| |
| Valve Core Remover |
Specifically designed to valve off system to remove valve core. |
 |
Part # |
Description |
| A32500 |
1/4" Valve Core Remover |
| |
| Valve Core Tool |
Hollow handle for storage. Furnished with 6 extra cores |
 |
Part # |
Description |
| A32004 |
1/4" Valve Core Tool |
| |
| Valve Cores |
Tefl on/Neoprene seal repl acemen t valve core |
 |
Part # |
Description |
| A31999 |
1/4" Valve Core (5 pk) |
| |
| Call for pricing or more information. |
|